R400 film

2021-06-26
R400 film
详细介绍:

CARESTREAM INDUSTREX R400 film


R400 film conforms to ASTM E 1815-96 Class II standard film, has the advantages of high speed, high contrast, and can bring you extremely fine-grained images. The powerful process performance provided by this film is simply unbelievable. It has good high temperature resistance, moisture resistance, anti-static and anti-scratch characteristics, so no matter what environment you work in, you can get the image you need.




Overview:


Carestream INDUSTREX R400 industrial film with patented T-grain emulsion technology has the advantages of high speed and high contrast, which can bring you extremely fine-grained images. At the same time, it is resistant to high temperature, humidity, static electricity and scratches. So no matter what environment you work in, you can get the images you need. You can use it for multi-film radiography, or for single-film technology, you can expose it directly by X-ray or use it with a lead intensifying screen.




Product specifications:


Product name

model

Specifications

Number of sheets per box

Number of boxes per box


Kodak (Carestream) Industrial Film


R400

14in×17in

100 sheets (with backing paper)

2 box

360mm*80mm

100 sheets (with liner paper)

10 box

300mm*80mm

100张(内附衬纸)

10 box


3. Flushing method:


Kodak INDUSTREXE R400 industrial film can be processed manually or automatically within a certain processing cycle.



4. Film storage conditions:


The temperature is 10℃~24℃, the relative humidity is 30%~50%, and it is far away from the radiation source (<90nGy/h).



5. Shelf life


See label.



6. Manual flushing:



Developer

Temperature

Suggested time

Stir

Acetic acid stop solution

Industrex Developer

20℃(68℉)

22℃(72℉)

24℃(75℉)

26℃(79℉)

5 Minutes

4 Minutes

3 Minutes

2 Minutes

Stir intermittently for 5 seconds, once every 30 seconds

30 to 60 seconds


(Continuous stirring at medium speed)


Industrex Fixer

3 to 6 minutes, stirring vigorously for 15 seconds, then every 30 seconds for 5 seconds