苏州聚友保利检测科技有限公司

National hotline:

0512-63230241

产品banner
Your current location HOME >> Products >> Fix Fixing Kit

Contact Us

Suzhou Jianbazi Testing Technology Co., Ltd

Landline:0512-63230241

                0512-63952861

                0512-63230242

URL:www.ndtsupmarket.com

Factory Address: No. 1, Gaocao North Road, Fuxiang Development Zone, Tongluo, Wujiang District, Suzhou City

Address of Wujiang Operation Center: 1802, Block G, Kaiping Business Center, the Taihu Lake New Town, Wujiang District, Suzhou

Shanghai Branch Address: No.16-153, Lane 199, Yefan Road, Yexie Town, Songjiang District, Shanghai


G-18 Industrial X-ray film processing kit (hand wash)

G-18 Industrial X-ray film processing kit (hand wash)

  • Classification:Fix Fixing Kit
  • Number of Views:second
  • Date of issue:2021-08-26 11:44:37
  • Product overview
  • Performance characteristics
  • technical parameter

G-18 Industrial X-ray film hand-washing processing flushing kit

user's manual

This set of medicine is a concentrated solution: it is suitable for various types of automatic developing machines to wash imported and domestic industrial X-ray nondestructive inspection films of various types to ensure that the films display clear radiographic images.


            

Specification

name

Component

Volume (liters)

Developing working fluid (38 liters)

Liquid A

5L*2

Fixing fluid (38 liters)

Liquid A

5L*2

Note: The red label is the developer, the blue label is the fixer


Preparation of developing working fluid


1. Add 27 liters of high-quality warm water.


2. Slowly add all the liquid A while stirring.


3 until it is evenly stirred;

The preparation method of the fixing solution is the same as that of the developer


1. Do not mix the fixing solution into the developer solution;


2. The container for the pharmaceutical liquid should be clean and clean

3. The liquid has strong irritation, pay attention to protection;


4. Configure the developing temperature control range to be 28-50C. When washing the film, the temperature should not exceed 20°C, which can be selected according to the model of the film processor;


5. The shelf life of this kit is 18 months;

Each set of medicine can be used to prepare 38 liters of developing working fluid and fixing working fluid.



label

近期浏览: